A structural insulated panel is two skins over a rigid foam core, and 100 to 200 mm of thickness is ordinary. That puts the cut edge close to the widest U channel made. Below the limit one channel does the work. At the limit the cover is built from two L profiles, and the lifting points stay on the panel rather than on the protector.
A thick edge with a soft middle
The skins are structural and the core is not. A knock on the edge compresses foam behind the skin, and the skin then loses its backing over a patch the size of a fist. Nothing shows until the panel is standing on a wall.
The channel has to reach past both skins and lie flat on each of them. A leg that stops on foam grips nothing and passes the knock straight into the core behind it.
When the inside width reaches the ceiling
Stock inside width ends at 150 mm and the three faces opened flat end at 260 mm. A 150 mm panel with 75 mm legs already passes that second figure, so geometry decides the build before thickness does.
Two L profiles back to back give the same three-sided cover with no folding limit, and a segmented channel covers a long run where no single blank will reach. Both are quoted per order against the panel drawing.
| Panel thickness | Edge build | Watch |
|---|
| Up to 100 mm | single U channel | leg clears both skins |
| 100 to 150 mm | single channel, short legs | opened width near 260 mm |
| Above 150 mm | two L profiles, back to back | joint line on the edge |
| Long run, any thickness | segments with a gap | no continuous fold |
| Angled or curved edge | cut segments | board will not follow a radius |
An open core does not forgive a knock
Once the panel is cut the foam is open to the air and to everything that touches it. A fingernail marks it, the edge of a strap cuts it, and a crushed core no longer presents the flat face that the next panel bears on.
Cover the edge before the panel leaves the bench. Cutting also throws dust onto the skins, and that dust travels into the joint, so brush the edge before the channel goes on.
Lifting points are not protection points
A panel of this thickness is heavy for its area, and a sling or a vacuum lifter takes the load through the panel. A paper channel used as a lifting pad will tear and drop the load, whatever its wall.
Mark the lift points and keep the channels between them, or stop the run short of each one. Send thickness, skin build and run length to mona@hengnicepacking.com for an edge build quoted per order.
Questions buyers ask before ordering
What is the thickest panel a U channel takes?
Around 150 mm inside width and only with short legs; thicker than that the cover is made from two L profiles.
Why two L profiles rather than one channel?
Opened flat, three faces of a thick panel pass the 260 mm folding limit, so the cover is built in two pieces.
Does the channel hold the panel together?
No. It covers the edge; the skins and the core carry every structural load.
Can a channel be used as a lifting pad?
No. The load path runs through the panel, and paper under a sling tears at the fold.
How is a cut edge prepared before packing?
Brush the cutting dust off and cover the edge at once, because the open core marks at a touch.