A paper U channel carries load as a short column, not as a hard material. The three closed faces work as one section, and the section only holds while all three are in contact. Wall thickness sets the capacity, leg length decides how much board bears the load, and inside width decides how far the column spans before it can buckle.
The section carries the load, not the board
Paper has little stiffness across its thickness, and a flat strip of it folds under very little. Fold the same board into three closed faces and the section gains a corner at each fold, and those corners resist a load applied to the edge.
Put the load on the spine of the channel and it travels down the two legs and along the base as a short column. Take one face away and the same board bends at the single fold instead.
Wall, leg and width: what each one does
Wall thickness comes first. Adding to it raises capacity out of proportion to the added mass, because the section gets thicker at every point at once, at the folds as well as on the faces.
Leg length works on bearing rather than on stiffness, spreading the load across more of the board. Inside width works against you, because a wide channel spans further before the legs begin to share the load.
| Variable | Effect | What to do |
|---|
| Wall thickness | largest single gain in capacity | raise it before anything else |
| Leg length | spreads load over more board | match it to the bearing face |
| Inside width | a wider section buckles sooner | keep it close to the panel |
| Moisture content | damp board folds earlier | keep the pack dry, fit dry |
| Edge contact area | a short bearing edge starts the fold | full contact along the leg |
Why a U beats an L of the same wall
An L profile has two faces and one fold, so a load on its corner twists the section and the free edge walks away from the board it should be pressing. The U has two folds and a closing face, and that twist is resisted at both ends.
The third face therefore has to bear. A U channel fitted so that one leg stands clear behaves like an L, with the extra weight and none of the gain, which is why fit matters as much as specification.
Describing the duty instead of naming a figure
A single load figure says little without the span, the board underneath and the humidity of the container. Two packs quoted to the same number behave differently once those three change.
Send stack height, the weight on the bottom edge, the panel material and the route, and the section is quoted per order against those conditions. That is more use than a figure nobody can check. Write to mona@hengnicepacking.com.
Questions buyers ask before ordering
What gives a U channel its strength?
The three closed faces acting as a short column, with a fold at each corner resisting the load on the edge.
Is a thicker wall always better?
For capacity yes, but it adds weight; leg length and a close inside width often gain more for less board.
Does a wider channel carry more?
No. A wider section spans further before the legs share the load, so capacity falls as width rises.
Why does moisture matter?
Wet board softens and folds earlier, so a dry pack and a dry fit keep the behaviour you were quoted.
Can you give a load rating in kg?
The section is quoted per order against stack height, edge load and route, because one figure does not transfer between packs.